5. Gently push the drive assembly into the bay until the drive stops.
6. Push the tray handle to the closed (locked) position.
7. If the drive was hot-swapped, check the hard disk drive status LED to verify that the
Confirming installation of the hard drive
About this task
Verify RAID HDD status:
1. On the SMI, click Server > Status Summary.
2. On the Status Summary page, verify that the RAID HDD Status field shows 2.
Verify the details of two hard drives:
1. On the SMI, click Server Configuration > Display Configuration.
2. On the Display Configuration page, verify that Disk devices shows the details of
Maintaining the Avaya S8800 Server for Avaya Aura
1
2
3
hard disk drive is operating correctly.
After you replace a failed hard disk drive, the green activity LED flashes as the disk
is accessed. When the new drive starts to rebuild, the amber LED flashes slowly,
and the green activity LED remains lit during the rebuild process. The rebuild
process takes approximately 30 minutes. An amber LED that remains lit indicates
a faulty drive that you must replace.
two hard drives.
Drive-tray assembly
Drive handle
Filler panel
®
Communication Manager
Replace the hardware components