Avaya S8800 Manual page 58

Hide thumbs Also See for S8800:
Table of Contents

Advertisement

Troubleshoot the Avaya S8800 Server
5. Replace the server.
SP LED lights up
The SP LED on the light path diagnostics panel lights up when an error occurs on the service
processor.
Troubleshooting steps
Procedure
1. Disconnect the server from the power source, and then reconnect the server to the
2. Report this error to your service provider for possible server replacement.
FAN LED lights up
The FAN LED on the light path diagnostics panel lights up when a fan fails, is operating too
slowly, or has been removed. The TEMP LED might also light up.
Troubleshooting steps
Procedure
1. Reseat the failing fan, which is indicated by a lit LED near the fan connector on the
2. Replace the server.
TEMP LED lights up
The TEMP LED on the light path diagnostics panel lights up when the system temperature
exceeds a threshold level. A failing fan can cause the TEMP LED to light up.
Troubleshooting steps
Procedure
1. Make sure that the room temperature is not too high.
2. Make sure that the air vents are not blocked.
3. Determine whether a fan has failed. If it has, replace the server.
58
Maintaining the Avaya S8800 Server for Avaya Aura
power source and restart the server.
system board.