Replace the Avaya S8800 Server and its components
7. Replace the air baffle over the memory modules. Make sure all cables are out of
8. Install the cover.
9. Reconnect the external cables and power cords.
10. Turn on the attached devices and the server.
Installing the DIMM air baffle
About this task
You must install the DIMM air baffle after you install a memory module.
Caution:
For proper cooling and airflow, replace the air baffle before you turn on the server. Operating
the server with a missing air baffle might damage server components.
Important:
Always use an electrostatic-discharge wrist strap or other grounding system when you work
inside the server. For more information, see
Procedure
1. Align the DIMM air baffle over the DIMMs so that the baffle pin on the left side of
26
Maintaining the Avaya S8800 Server for Avaya Aura
the way.
When you install or remove memory modules, the server configuration information
changes. When you restart the server, if a monitor and keyboard are connected,
the system displays a message that indicates that the memory configuration has
changed.
the air baffle aligns with the pin hole next to the DIMM connector on the system
board. See the following figure.