Troubleshoot the Avaya S8800 Server
4. Reconnect the power cords, and restart the server.
5. Check the amount of system memory.
6. If the problem still exists, replace the server.
Multiple rows of DIMMs in a branch are identified as failing
Troubleshooting steps
About this task
Procedure
1. Reseat the DIMMs.
2. Restart the server.
3. Remove the lowest numbered DIMM pair of those that are identified and replace it
4. Repeat Step 3 as necessary. If the failures continue after all identified pairs are
5. Return the removed DIMMs, one pair at a time, to their original connectors. Restart
6. Replace each DIMM in the failed pair with an identical known good DIMM. Restart
7. Replace the failed DIMM. Repeat steps 5 and 6 until you have tested all removed
8. Replace the lowest numbered DIMM pair of those identified. Then, restart the
9. Repeat Step 8 as necessary.
52
Maintaining the Avaya S8800 Server for Avaya Aura
with an identical pair of known good DIMMs. Then, restart the server.
replaced, go to step 8.
the server after each pair, until a pair fails.
the server after each DIMM.
DIMMs.
server.