Alcatel-Lucent 1665 Installation Manual page 45

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Physical and power installation
............................................................................................................................................................................................................................................................
Qty.
1
1
1
1
2 or 3
1
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
Description
Ohmmeter
ITE-6379C
DS1/E1 Error Rate Test Set
ITE-7113
DS3/EC1 Error Rate Test
Set
ITE-7113
Optical Test Set (Optional)
LC-type Optical Fiber
Jumper ITE-7169
(108918269)
15-dB LC-type LBO ITE-
7196 (108279480)
Noyes OFS 300-200X
Optical Fiber Scope
ITE-7129
2.5mm Universal adapter
cap ITE-7129 D1
1.25mm Universal adapter
cap ITE-7129 D2
Noyes VFS-1 ITE-7187
1
Video Fiber Scope
Individual presaturated
alcohol wipes ITE-7136
Comments
An ohmmeter is required to verify that the Alcatel-
Lucent 1665 DMXtend is properly grounded.
A DS1/E1 error rate test set is required for testing of
DS1/E1 cabling. A T-BERD 2209 or equivalent is
recommended.
A DS3/EC1 error rate test set is required for testing of
DS3/EC1 cabling. A T-BERD 209 or equivalent is
recommended.
A Optical test set is required for testing of low speed
optics OC3/12/48. An Omniber 718 or equivalent is
recommended.
Two optical fiber jumpers with LC type connectors are
required to optically loop the Alcatel-Lucent 1665
DMXtend shelf for test purposes. In addition, for
shelves containing optical circuit packs in any of the
function unit slots, a single optical fiber jumper is
required for testing of the individual ports.
LBOs are only required when optically looping the
Alcatel-Lucent 1665 DMXtend shelves containing
optical circuit packs in any of the function unit slots; a
single 15-dB LBO is required for testing of the
individual ports
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the optical fiber scope may not be needed
For use with the Noyes OFS 300-200X Optical Fiber
Scope
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the video scope may not be needed
99% pure isopropyl alcohol
I- 3