Alcatel-Lucent 1665 Installation Manual page 189

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
Setting DS1/E1 LBOs
........................................................................................................................................................................................................................
1
Log on to the Alcatel-Lucent 1665 DMXtend shelf using the CIT software as described in
the
"Use of WaveStar
........................................................................................................................................................................................................................
2
See the following table of cable lengths and LBO values. Determine the LBO value
corresponding to the DS1/E1 cables installed.
........................................................................................................................................................................................................................
3
Use the
........................................................................................................................................................................................................................
4
Double-click on a Function Group where the
LNW7/LNW8/LNW112/LNW39/LNW391/LNW801/LNW84 is located.
........................................................................................................................................................................................................................
5
Select VT Group1 and the first DS1/E1 in that group.
Result:
........................................................................................................................................................................................................................
6
Select Line Build Out 20 (0,133) from the drop-down window.
........................................................................................................................................................................................................................
7
Select Apply to: All Ports, This Pack
........................................................................................................................................................................................................................
8
Apply
Click
Result:
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
®
CIT software" (p.
LBO value
20
40
60
80
100
window click on
GUI
A provisioning page will be displayed.
to issue the command.
All DS1/E1 ports will have a LBO value of 20 for this pack.
5-6).
Distance (feet)
Cable type 1161A
0 - 133 (default)
133 - 267
267 - 420
420 - 550
550 - 655
Configuration:Equipment
command.
6 - 5