Circuit pack installation
............................................................................................................................................................................................................................................................
To protect against damage due to electrostatic discharge, a properly grounded ESD wrist
strap must be worn when handling equipment.
LNW2 (SYSCTL) installation
Follow this procedure to install the LNW2 (SYSCTL) circuit pack into the Alcatel-Lucent
1665 DMXtend shelf.
........................................................................................................................................................................................................................
1
Remove the SYSCTL circuit pack from the packing material.
........................................................................................................................................................................................................................
2
Identify the CTL slot on the Alcatel-Lucent 1665 DMXtend shelf. See
"Alcatel-Lucent 1665 DMXtend shelf" (p.
........................................................................................................................................................................................................................
3
Place the SYSCTL circuit pack into the CTL slot on the Alcatel-Lucent 1665 DMXtend
shelf. Do NOT engage the circuit pack in the backplane connector.
........................................................................................................................................................................................................................
4
Check off the appropriate box in the
E
O
N D
........................................................................................................................................................
OC-3/OC-12/OC-48/OC-192 main OLIU installation
Follow this procedure to install the following OC-3/OC-12/OC-48/OC-192 main OLIU
circuit packs in the Alcatel-Lucent 1665 DMXtend shelf.
LNW38 OC-12 IR
LNW40 OC-3 IR
LNW41 OC-48 PTM
LNW51 OC-12 LR
............................................................................................................................................................................................................................................................
4 - 1 0
CAUTION
177D or LNW98 Apparatus Blanks are required in all unequipped D and G
function unit slots to provide proper air flow for cooling.
LNW42 or LNW95 Apparatus Blanks are required in all unequipped Main slots
to provide proper air flow for cooling.
LNW43 or LNW96 Apparatus Blanks are required in all unequipped A/B slots
to provide proper air flow for cooling.
CAUTION
ESD hazard