Alcatel-Lucent 1665 Installation Manual page 210

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
7
Click on the
Result:
There should be no alarm indications on the Alcatel-Lucent 1665 DMXtend shelf.
........................................................................................................................................................................................................................
8
Remove PTM if necessary and the 15-dB LBO from OC-3 OLIU from (port 1) and plug it
into the IN connector directly below it (port 2).
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 2).
........................................................................................................................................................................................................................
9
Connect the Port 2 IN connector to the Port 2 OUT connector (at the LGX) of the OC-3
OLIU, using an optical fiber jumper cable.
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-3 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
10
Repeat
........................................................................................................................................................................................................................
11
Repeat this entire procedure for each LNW37 PTM equipped in the Alcatel-Lucent 1665
DMXtend shelf.
........................................................................................................................................................................................................................
12
Replace all protective dust covers on the LNW37 PTM connectors (OLIU and LGX), that
were removed to perform this procedure.
........................................................................................................................................................................................................................
13
Check off the appropriate box in the
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
6 - 2 6
Configuration > Update System > Update All
The flashing FAULT LED should extinguish on the OC-3 OLIU.
The FAULT LED on the OC-3 OLIU will begin flashing and the MN and NE
Step 2
to
Step 9
for OLIU ports 3 and 4.
S
F
T E P S
"Installation checklist" (p.
II-5).
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013