Alcatel-Lucent 1665 Installation Manual page 215

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
8
Remove PTM if necessary and the 15-dB LBO from OC-12 OLIU from (port 1) and plug
it into the IN connector directly below it (port 2).
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 2).
........................................................................................................................................................................................................................
9
Connect the Port 2 IN connector to the Port 2 OUT connector (at the LGX) of the OC-12
OLIU, using an optical fiber jumper cable.
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-12 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
10
Repeat
........................................................................................................................................................................................................................
11
Repeat this entire procedure for each LNW49 or LNW55 PTM equipped in the Alcatel-
Lucent 1665 DMXtend shelf.
........................................................................................................................................................................................................................
12
Replace all protective dust covers on the LNW49 or LNW55 PTM OC-12 OLIU
connectors (OLIU and LGX), that were removed to perform this procedure.
........................................................................................................................................................................................................................
13
Check off the appropriate box in the
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
The FAULT LED on the OC-12 OLIU will begin flashing and the MN and NE
Step 2
to
Step 9
for all OLIU ports.
S
F
T E P S
"Installation checklist" (p.
II-5).
6 - 3 1