Alcatel-Lucent 1665 Installation Manual page 219

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
4
Remove the optical fiber jumper from the OC-48 OLIU (at the LGX).
Result:
and NE LEDs should be lit on the SYSCTL circuit pack.
........................................................................................................................................................................................................................
5
If not still connected from the previous procedure. Connect the Front CIT cable between
the PC and the CIT/RS 232 port or OSI front LAN port of the System Controller and login
to the shelf using the serial/LAN connection and the GUI options on WaveStar
........................................................................................................................................................................................................................
6
Use the
........................................................................................................................................................................................................................
7
Click on the
Result:
There should be no alarm indications on the Alcatel-Lucent 1665 DMXtend shelf.
........................................................................................................................................................................................................................
8
Remove PTM if necessary and the 15-dB LBO from OC-48 OLIU from (port 1) and plug
it into the IN connector directly below it (port 2).
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 2).
........................................................................................................................................................................................................................
9
Connect the Port 2 IN connector to the Port 2 OUT connector (at the LGX) of the OC-48
OLIU, using an optical fiber jumper cable.
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-48 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
10
Repeat
........................................................................................................................................................................................................................
11
Repeat this entire procedure for each LNW62, LNW55, LNW402 PTM equipped in the
Alcatel-Lucent 1665 DMXtend shelf.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
The FAULT LED should begin flashing on the OC-48 OLIU and only the MN
GUI
window to send the
Configuration > Update System > Update All.
The flashing FAULT LED should extinguish on the OC-48 OLIU.
The FAULT LED on the OC-48 OLIU will begin flashing and the MN and NE
Step 2
to
Step 9
for OLIU ports 3 and 4.
upd-sys
command.
®
CIT.
6 - 3 5