Alcatel-Lucent 1665 Installation Manual page 174

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone node setup
........................................................................................................................................................................
Steps
................................................................................................................................................
1
Fully insert one or both (if two are equipped) M1 and M2 OLIUs into the shelf.
Note:
circuit pack into the slot until it is fully seated. Then close the faceplate latch and
tighten the retainer screw on the other end.
Note:
dividers removed. See
(p. 2-5)
Note:
with LNW55 OC3/OC12/OC48, LNW84 OC3/OC12/OC48, LNW705 XM10G/8,
and/or LNW785 OMD, circuit packs. This shelf cover provides more space to prevent
fibers from touching the front cover when the cover is closed.
................................................................................................................................................
2
Fully seat LNW42 or LNW95 Apparatus Blanks in any unequipped Main slots. For
LNW141 or LNW84 main OLIUs the center divider must be removed and in the unused
slot a LNW98 apparatus blanks installed to provide proper air flow for cooling.
Note:
circuit pack into the slot until it is fully seated. Then close the faceplate latch and
tighten the retainer screw on the other end.
................................................................................................................................................
3
If the LNW41 (OC-48), LNW141 (OC-192) or LNW84 (OC-3/OC-12/OC-48) mains are
being used, insert the PTMs at this time. See
insertion.
................................................................................................................................................
4
Connect IN to OUT on the OLIU in the M1 slot of the Alcatel-Lucent 1665 DMXtend
shelf using an optical fiber jumper cable and a 15-dB LBO. See
cleaning"
........................................................................................................................................................................
5 - 4
CAUTION
Equipment damage
The LNW38, LNW40, LNW51, LNW302, LNW382, and LNW601 OLIU circuit
packs are equipped with optics that do not meet GR-78 R9-3 requirements on
ESD susceptibility. Always use proper ESD procedures when handling these
OLIU circuit packs to avoid equipment damage.
Using a gentle steady pressure on both ends of the circuit pack, slide the
The LNW141, and LNW84 require shelf comcode 849031372 with the center
Chapter
to remove the dividers
A deeper shelf cover (comcode 849064282) is required for shelves equipped
Using a gentle steady pressure on both ends of the circuit pack, slide the
for proper fiber cleaning instructions.
2,
"Alcatel-Lucent 1665 DMXtend center divider"
Appendix B, "PTM modules"
for proper
Appendix A, "Fiber
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013