Chapter 12 Serial Port (SIO)
12.4

Serial Port Operation Description

12.4.1 Data Format

(1) UART mode
The data format for the UART mode is shown in Figure 12-3.
SRCON0/1 and STCON0/1 can be set to specify a data bit length of 5 to 8 bits. The parity bit can be
enabled/disabled. If enabled it can be set to even or odd. Stop bit length can be set to 1 or 2 bits.
The combination of these parameters gives a range of from 7 to 12 bits for send/receive data frames.
Start
bit
• 1 frame
MAX ...... 12 bits
MIN ....... 7 bits
(2) Synchronous mode
The data format for the UART mode is shown in Figure 12-4.
SRCON0/1 and STCON0/1 can be set to specify a data bit length of 5 to 8 bits. The parity bit can be
enabled/disabled, and if enabled can be set to even or odd.
The combination of these parameters gives a range of from 5 to 9 bits for send/receive data frames.
• 1 frame
MAX ....... 9 bits
MIN ........ 5 bits
OPTION A (C): 1.5 V (3.0 V), Without regulator
circuit for LCD bias
1
2
3
4
Data bit
Figure 12-3 UART Mode Data Format
1
2
3
4
Data bit
• Data bit length: 5 to 8 bits, variable
• Parity bit: enable/disable
Figure 12-4 Synchronous Mode Data Format
1 frame
5
6
7
8
• Data bit length: 5 to 8 bits, variable
• Parity bit: enable/disable
Odd/even select
• Stop bits: 1 or 2 stop bits select
1 frame
5
6
7
8
Odd/even select
12 – 12
OPTION B (D): 1.5 V (3.0 V), With regulator
Parity
Stop
Stop
bit
bit
bit
Parity
bit
circuit for LCD bias