Maintenance

6.5 Servicing the pneumatic system

6.5.1 Disconnecting the compressed air supply

Fig. 248: Disconnecting the compressed air supply
(1) - Handle
To disconnect the compressed air supply:
1. Pull the handle (1) on the compressed air maintenance unit to the left.

6.5.2 Adjusting the operating pressure

Proper setting
Refer to the Technical Data ( p. 351) chapter for the permissible
operating pressure. The operating pressure cannot deviate by more
than ± 0.5 bar.
Check the operating pressure on a daily basis.
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
NOTICE
Property damage from incorrect adjustment!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.