Fig. 243: Cleaning the incision device for piping ends (2)
(3) - Linear guides
5. Move the linear guide (3) by hand while carefully cleaning all areas
6. Replace the piping strip rest table (2).
7. Re-tighten the screws (1).
8. Re-assemble the pick-up folder.
9. Switch on the machine.
 The machine completes a reference run and is afterwards ready for

6.3 Replacing the incision knives for piping ends

To replace the knives of the incision device for piping ends:
1. Remove the pick-up folder.
2. Via software: Select Service menu > Machine test > Test
294
with compressed air.
sewing.
WARNING
Risk of injury from sharp parts!
Punctures and cutting possible.
Switch off the machine prior to any maintenance
work.
piping knife
> Referencing
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021