Maintenance Work; Pneumatic System; Setting The Operating Pressure - Dürkopp Adler M-TYPE H867 Service Manual

Table of Contents

Advertisement

Maintenance work

20 Maintenance work

20.1 Pneumatic system

20.1.1 Setting the operating pressure:

Correct setting
The operating pressure is 6 bar.
Check the pressure on the pressure indicator every day. The pressure
must not deviate from the reference pressure by more than 1 bar.
Figure 68: Setting the operating pressure
Setting steps
1. Pull the turning handle (1) up.
2. Turn the turning handle until the pressure indicator (2) indicates 6 bar:
3. Push the turning handle (1) down.
Service manual H867 Version 00.0 - 08/2013
ATTENTION
Machine damage due to incorrect pressure
An incorrect pressure can cause damage to the machine. Make sure
that the machine is only used when the operating pressure is set cor-
rectly.
1
6
4
8
2
10
2
0
(1) - Turning handle
(2) - Pressure indicator
• To the right: To increase pressure
• To the left: To reduce pressure
83

Advertisement

Table of Contents
loading

Table of Contents