Changing Needles - Dürkopp Adler 755 B Operating Instructions Manual

Table of Contents

Advertisement

4.5 Changing needles

Fig. 5: Changing needles
(1) - Needle holder
(2) - Screws
To change the needles:
1. Swivel the folder station out ( p. 18).
 The needles are freely accessible.
2. Loosen the screws (2) and remove the needles from the needle
3. Insert new needles into the holes of the needle holders (1) until they
20
CAUTION
Risk of injury from sharp parts!
Punctures or cutting possible.
Only change needles with the main switch turned
off.
When changing the needles, NEVER reach into
the area of the middle knife.
NOTICE
Property damage may occur!
When switching to needles with a different needle strength the
needle can be damaged by the hook.
Readjust the needle guard at the hook.
holders (1).
reach the stop (use only the correct needles  p. 351).
(3) - Needle groove left needle
(4) - Needle groove right needle
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
Operation

Advertisement

Table of Contents
loading

This manual is also suitable for:

756 b756 f

Table of Contents