Operation
Operating Instructions 52Xi, 52Xi-75 - 03.0 - 09/2023
4.3

Inserting/replacing the needle

WARNING
Risk of injury from needle and moving parts!
Switch off the machine before you insert or
replace the needle.
Do not touch the tip of the needle.
Order
Adjust the distance between the needle and the hook point after
replacing to a different needle thickness ( Service Instructions).
NOTICE
Damage to the machine, needle breakage, or thread
damage is possible due to incorrect distance between the
needle and hook point.
A false orientation of the needle may damage the hook
point.
Check the distance to the hook point after inserting a needle
with a different thickness. Reset distance if necessary.
Disturbance by an incorrect hook clearance
After inserting a thinner needle:
• missing stitches
• thread damage
After inserting a thicker needle:
• damage to the hook point
• damage to the needle