Parameterization
8.4 Settings
Archiving/MMI (MMI: Man Machine Interface)
In this group, you enter the address of a server to which you can send images and/or data records
for diagnostics.
Table 8-22
Archiving/MMI
Parameter
Possible values
IP address
xxx.xxx.xxx.xxx
Port
Device-specific
Time limit
0 ... 3600
Remote client
xxx.xxx.xxx.xxx
Correlations and dependencies of the parameters
Table 8-23
Correlations and dependencies of the parameters
Parameter
Dependency
PROFINET IO
IP mode
Host name
PROFINET IO device name
PROFINET IO device
Host name
name
8.4.1.2

Use

You define the signal and communication paths in this area. For example:
• The path signals must take to reach the camera
• The communication path that is used to output a modified result string
94
Default
Description
192.168.0.45
IP address of the server for diagnostic information
8765
Corresponding port of this server
10
0: There is no transfer of cyclic monitoring frames to test
the connection between the camera and the server.
Otherwise: Time in seconds after which a monitoring
frame is sent to test the connection between the cam‐
era and the server. If the server does not respond to this
frame within the monitoring time, an error is output
(only when the camera is in RUN or "Save program"
mode) and the connection is reestablished.
0.0.0.0
IP address of the HTTP client that is permitted to execute
remote functions such as the remote XML command.
To deactivate the remote functions via this connection, en‐
ter "0.0.0.0".
Description
The parameters of the "PROFINET IO" group are only active
when the "PROFINET (FB79)" IP mode is selected.
The host name only corresponds to the "PROFINET IO de‐
vice name" when the "PROFINET (FB79)" IP mode is selec‐
ted.
The "PROFINET IO device name" only corresponds to the
"Host name" when the "Manual" IP mode is selected.
Note
If the "PROFINET (FB79)" IP mode is not set, the "Device
name" corresponds to the "Host name".