Parameterization
8.5 Device
Data records
In this group, you receive diagnostics information on the data records.
Table 8-38
Data records
Parameter / Action
Number
Contents
Open & Save
Save as CSV
Reset
System image
In this group, you can save a complete system image in a diagnostics package.
Note that saving a complete system image may take a few minutes. The WBM informs you about
the progress of the save operation. To ensure error-free operation, the camera must not be
operated during this time.
112
Description
You can see the number of diagnostics events currently in the event buffer without those
stored persistently.
With the following check boxes, you select the information you want to display about the
diagnostics events in the buffer:
Error: Information on the occurrence and acknowledgment (manual or automatic)
of errors
Note
If only the "Error" check box is selected and you have selected the "Ring" buffer type,
all buffer entries are retained.
When the buffer is completely full, no further entries can be made.
To delete the contents of the buffer, you must click the "Reset" button in this case.
Results: First 1000 characters of the processing result
Image: Information on image acquisition, e.g. exposure time, brightness
States: Mode change (change to RUN, CALIBRATE, self-test, etc.)
Control: Change of control of the camera (control by WEB, CPU)
Diagnostics: Changes that affect diagnostics, e.g. changing the diagnostics options
or fetching a time stamp from an SNTP server.
Security: Security relevant events
This contains events that occurred within the application. You can receive a full list
of all events via the Syslog messages (see below) or via the security events that are
transferred to the Syslog servers.
Note that you need the rights to "View security relevant events" ("Settings" → "Se‐
curity") for this purpose.
Clicking the "Open & Save" button opens a webpage with the events contained in the
event buffer selected under "Contents". You can save this webpage on your PC.
If you select the "with persistent" check box, the data records stored permanently on the
camera are displayed and stored on your PC.
When you click the "Save as CSV" button, a dialog box opens in which you can store the
events currently selected under "Contents" as a CSV file.
If you select the "with persistent" check box, the data records stored permanently on the
camera are also entered in the CSV file.
Click the "Reset" button to delete all the entries in the event buffer, including the entries
relating to temporary errors. Data records stored permanently on the camera are re‐
tained.