WBM login when accessing via an automation system (DISA active)
If the camera is controlled by an automation system, i.e. if the DISA bit is set, you will need to log
in to the camera as follows:
1. Make sure that only one PC is accessing the camera (padlock with red/gray marking).
2. Place the mouse pointer on the currently logged-in user (top right) and click.
This takes you to the "Settings" → "Security" page.
3. Log in as "User1" or "Service" to take over control of the camera. This is only possible if the
"Take control" check box has been selected for that user.
Note
Limited control
Note that the automation system can only control the device to a limited extent once you take
over control with "Take control". This is relevant for functions that require the DISA bit, e.g.
change program and save program.
SIMOCRANE CenSOR
Operating Instructions, 07/2021
Parameterization
65