Parameter
Cause
Remove NOK picture of
a series with OK result
Record
Buffer size
Report
Buffer type
Match string frames
SIMOCRANE CenSOR
Operating Instructions, 07/2021
Possible values
Default
Trigger
Read OK
Read NOK
Read OK (all)
Read NOK (all)
Match OK
Match NOK
Save program
Quality evaluation
good
Quality evaluation
fair
Quality evaluation
poor
☐ / ☑
Image
Image
± 1 image
1 ... 50
50
Ring
Ring
Stack
☐ / ☑
Description
Specify what causes an image to be saved.
Read NOK
For a detailed description of this parameter, see the
Save program
paragraph below this table.
In "Scan" mode (or program sequence) and when
"Cause = Read NOK (all)", images that have already
been saved with this cause are removed from the di‐
agnostics buffer if successful processing takes place
within the series.
Note
Note that when diagnostics transfer is activated, diag‐
nostic images may already be transferred or prepared
for transfer before successful processing takes place.
These images are then transferred completely.
Image
If one or more of the causes selected above occurs,
the current image is saved.
± 1 image
Not only the current image but also the previous
and the next image are saved.
Defines the number of images that are to be buffered
in the diagnostics memory.
Note that you can increase the buffer size available for
the diagnostics transfer ("Settings" → "Communica‐
tion" → "Use" → "Diagnostics transfer") by reducing the
size of this buffer.
Type of buffer:
Ring: When the buffer contains 15000 entries, en‐
tries 1, 2, ... are overwritten.
Stack: When the buffer contains 15000 entries, no
further entries are made.
The command "Write match string" or "Write string
trigger synchronized" outputs received frames to the
diagnostic report.
Parameterization