Parameterization
8.4 Settings
Description of the "Cause" parameters
• Trigger
Not relevant for CenSOR
• Read OK
Each successfully processed image is saved.
• Read NOK
Each image for which processing has failed is recorded.
• Read OK (all)
Each successfully processed image is saved.
• Read NOK (all)
Each image for which processing has failed is recorded.
• Match OK
Not relevant for CenSOR
• Match NOK
Not relevant for CenSOR MV540 H
• Save program
Images used for saving programs are saved.
• Quality evaluation good
All images with a good quality evaluation are saved. Corresponds in terms of behavior to the
"Read OK" setting in "Scan" mode (or program sequence).
• Quality evaluation fair
Not relevant for CenSOR
• Quality evaluation poor
Not relevant for CenSOR
Time basis
In this group, you specify the source for the time stamp of the diagnostics events.
Table 8-29
Time basis
Parameter
Source
IP address
Synchronize
102
Possible values
PC
SNTP
xxx.xxx.xxx.xxx
--
Default
Description
PC
PC
The PC provides the time stamp.
SNTP
An SNTP server (SNTP = simple network time pro‐
tocol) in the network provides the time stamp.
192.168.0.44
IP address of the SNTP server (only active if "Source =
SNTP")
--
When you click this button, the time stamp of the se‐
lected source is transferred from the camera. Note that
when you change the "Source" parameter, you must
save the change in the camera before synchronizing.