Bti7814 Ac Pem - Juniper BTI7800 Series Hardware Overview And Installation Manual

Table of Contents

Advertisement

BTI7800 Series Hardware Overview and Installation Guide
Table 18: BTI7814 14-Slot Chassis DC Power Entry Module (BT8A78PEM3-DC) Specifications (continued)
Item
LEDs
1
Before using for planning or implementation purposes, contact Juniper Networks Support to confirm the power consumption
values.
2
Input voltages outside this range might cause the chassis to operate unpredictably.
44
Specification
LED
Name
Ch 1 to 6
Fuses 1 to 6
ACT
Active
H/S
Hot Swap
REV
Reverse
voltage
NOTE:
The REV LED indicates red to alert the installer that the chassis has
been wired in reverse polarity. The installer should switch the power OFF on
the chassis and rewire the positive and negative connections to the correct
power terminals.

BTI7814 AC PEM

The BTI7814 chassis can be powered by four fan-cooled 2900W (53.5V) AC Rectifier
Modules (BT8A78ACM1). The four rectifier modules and the housing are included when
you order the chassis with the AC option (BT8A78CH14-KIT2-AC, BT8A78CH14-KIT3-AC).
It is recommended that you install your chassis with all four rectifiers.
NOTE:
The BTI7814 chassis can also be powered by an external rectifier. For
information on the external, standalone, Power-One
rectifier, see
"AC Rectifier" on page
Color
State
Red
Off
On
Blinking
Green
On
Blue
Off
Blinking
On
Red
Off
On
203.
Copyright © 2019, Juniper Networks, Inc.
Description
Normal operation.
Fuse is blown or not present.
Input power is lost.
Normal operation.
Normal operation.
The power circuit is still active
and starting to shut down.
The PEM is ready to be
removed.
Normal operation.
The wiring is reversed.
®
rack-mounted 1U

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bti7814Bti7802Bti7801Bt8a78ch14Bt8a78ch2-i02Bt8a78ch1

Table of Contents