Replacing a BIC

Installing or Removing a BIC Filler Panel

128
NOTE:
The BIC can also be placed in hot-swap mode if the BIC is
administratively disabled, or if the containing UFM is administratively
disabled.
Loosen the BIC faceplate thumbscrew, located at the top of the BIC. Use a screwdriver
5.
if necessary.
When the H/S LED is solid blue, attach the extractor tool to the hole in the bottom
6.
latch and pull simultaneously on the top handle and on the extractor tool.
Gently slide the module all the way out from the UFM.
Place the module into an antistatic bag.
7.
Attach a BIC filler panel to cover the empty BIC slot.
8.
You have successfully completed this procedure.
Use this procedure to replace a BIC. If you want to replace both BICs in a UFM, you must
replace one BIC at a time.
Follow the procedure in
1.
Remove only one BIC from the UFM.
Follow the procedure in
2.
Repeat this procedure if you want to replace the other BIC.
NOTE:
If you accidentally remove both BICs from the UFM, perform a warm
reload of the UFM after you install the replacement BICs (
).
ufm
Use this procedure to install or remove a BIC filler panel.
Filler panels should always be used to fill an open BIC slot to maintain system temperature
and prevent debris from entering the system.
"Removing a BIC" on page 126
"Installing a BIC" on page 125
to remove a BIC.
to install the replacement BIC.
system reload warm