Service Module LEDs

Table 52: Service Module LED Behavior

Name
Description
Identify
The Identify LED indicates
whether the CMM has
(AMBER)
identified and
acknowledged the
newly-inserted module.
Copyright © 2019, Juniper Networks, Inc.

Figure 51: Remove the Lug

Remove the FMD96 from the frame or the rack.
3.
a. Position one person on each side of the FMD96 to secure the FMD96 during removal.
b. Remove the mounting screws and washer for each mounting bracket attachment.
c. Remove the FMD96 from the frame or the rack.
d. Place the FMD96 in antistatic packaging and stow in accordance with the
environmental storage conditions.
You have successfully completed this procedure.
The following table describes the LEDs for all service modules.
State
OFF
ON
BLINKING
Chapter 5: BTI7800 Series Modules
State Description
The CMM has identified and acknowledged the module.
The CMM can only acknowledge the module if the
module is administratively up. A newly-inserted module
is administratively up if either of the following is true:
The module has been pre-provisioned and configured
to be administratively up.
Auto-provisioning is enabled. If auto-provisioning is
enabled and if the CMM is able to identify the module,
the module is automatically provisioned and its
administrative status is set to up.
The CMM has failed to identify or acknowledge the
module.
The CMM is attempting to identify and acknowledge the
module.