Wps4 Latches; Table 50: Wavelength Protection Group Specifications - Juniper BTI7800 Series Hardware Overview And Installation Manual

Table of Contents

Advertisement

BTI7800 Series Hardware Overview and Installation Guide

Table 50: Wavelength Protection Group Specifications

Parameter
Operating wavelength range
Insertion Loss Cn_IN to LnA_OUT (C-band)
Insertion Loss Cn_IN to LnB_OUT (C-band)
Insertion Loss LnA_IN to Cn_OUT (C-band)
Insertion Loss LnB_IN to Cn_OUT (C-band)
Monitor Range (Cn_In)
Monitor Range (LnA_In)
Monitor Range (LnB_In)
Monitor Accuracy
Directivity (LnA_IN to LnB_IN
Directivity (LnA_OUT to LnB_OUT)
Switch Isolation
Polarization Dependent Loss
Polarization Mode Dispersion
Return Loss
Switching Time

WPS4 Latches

138
CAUTION:
Cn IN, LnA IN, LnB IN must be limited to Class 1M (21.3 dBm) Laser
Safety Regulations.
)
The top and bottom latches of a WPS4 must be fully closed for proper module operation.
A WPS4 module has one of two types of top latches.
"WPS4 Latches" on page 138
Minimum
Maximum
1260
1620
2.7
4.2
2.7
4.2
0.3
1.8
0.3
1.8
-25.0
23.0
-40.0
18.0
-40.0
18.0
-1.3
1.3
45.0
-
45.0
-
50.0
-
-
0.2
-
0.1
40.0
-
-
50.0
"WPS4 Latches" on page 138
show a type of top latch in the open and closed positions.
Copyright © 2019, Juniper Networks, Inc.
Units
nm
dB
dB
dB
dB
dBm
dBm
dBm
dB
dB
dB
dB
dB
ps
dB
ms
and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bti7814Bti7802Bti7801Bt8a78ch14Bt8a78ch2-i02Bt8a78ch1

Table of Contents