Table 22: BTI7800 Series Component Power Consumption (at 40°C) (continued)
Module
QSFP28 100GE LR4
QSFP28 100GE Ethernet/OTN LR4
QSFP28 100GE SR4
CFP 100GBASE-SR10 100m
CFP 100GBASE-LR4 10km
100G Coherent CFP
100G Coherent CFP-M05

Cooling

BTI7814 Cooling System

Copyright © 2019, Juniper Networks, Inc.
PEC
QSFP-100G-LR4-2
(740-074685)
QSFP-100G-LR4-D
(740-073859)
QSFP-100GBASE-SR4
(740-058734)
BP3AMASS
BP3AMDLI
BP3AMCTL
CFP-100GBASE-CHRT
BTI7814 Cooling System on page 55
BTI7802 Cooling System on page 58
BTI7801 Cooling System on page 60
The BTI7814 system uses four 14-Slot Chassis Front Cooling Modules (FAN3) to supply
front-to-back air flow through the chassis. When one or more UFM6 modules are installed
in the chassis, two BTI7814 Booster Fan modules are required to provide additional
cooling. For information, see
The figure below shows two FAN3 cooling modules on the left side of the chassis. There
are two more FAN3 cooling modules on the right side of the chassis (not shown). Each
cooling module is connected to the chassis independently from the other cooling modules,
and each fan is controlled independently by the Chassis Management Module (CMM).
The fans typically work at 60 percent of the maximum fan speed.
Cool air is drawn in from the front of the chassis and exhausts to the rear.
Typical (W)
10
20
25
"BTI7814 Booster Fans" on page
Chapter 2: BTI7800 Series Chassis
Maximum (W)
3.5
3.5
3.5
12
24
30
32
57.
55