Figure 63: Connect a Grounding Cable to the PTX10004
6. Place the two screws with attached washers over the grounding lug and grounding cable.
7. Tighten the two M-6 screws using a Pozidriv or Phillips screwdriver.
8. Dress the grounding cable and ensure that it doesn't touch or block access to other device components
and that it doesn't drape where people can trip over it.
SEE ALSO
JNP10K-PWR-AC2 Power Supply | 54
Install a JNP10K-PWR-AC2 Power Supply | 177

Connect AC Power to a PTX10004

After you ground the chassis, add power supplies, and apply power to the chassis, the system initiates the
power-on sequence. This sequence can start incrementally with a single power supply, but we do not
recommend that you bring up a PTX10004 system with less than three power supplies.
Before you begin to connect power to the router, be sure you understand how to prevent ESD damage.
See
"Prevention of Electrostatic Discharge Damage" on page
To connect AC power to a PTX10004 chassis:
1. Connect the chassis to earth ground (see
298.
"Connect the PTX10004 Router to Earth Ground" on page
149
147).