Download Print this page

Avaya S8300 Manual page 64

Converting media server between icc and lsp modes
Hide thumbs Also See for S8300:

Advertisement

Migrating a G350 LSP to a G700 LSP (Communication Manager 2.1 or later)
16. Access the G700's
console port and set up
the G700 IP addresses
and the gateway's
controller list.
Start on page 533.
17. Verify that the media
gateway has registered
with the primary
controller.
18. Set time, date, and time
zone.
Page 259.
19. Install post-conversion
service pack file, if any.
Page 260.
20. Install the G700 LSP
license file.
Starting on page 262.
21. Install the authentication
file.
Starting on page 264.
22. Configure server.
Starting on page 464,
ending on page 478.
23. Reboot the LSP.
64 Converting an Avaya S8300 Media Server Between ICC and LSP Modes
Task
On the LSP's primary controller
Steps/Comments
On the gateway's MGP
Assign IP addresses to the gateway components.
Enter the IP addresses of the primary controller
and up to three alternate controllers.
Set the G700 LSP transition points.
Reset MGP
Open a SAT session and enter list
media-gateway. Verify that the Registered field
(Reg?) is set to y.
Place a test call.
On the LSP
The time of the LSP must be set to the same time zone as
its primary controller, even if the LSP is physically located
in a different time zone.
Skip the Verify Media Server Configuration section
starting on page 247.
Fill in each Configure Server screen with data for
the LSP.
On the Configure Local Survivable Processor
screen, select one of the three LSP choices
depending on the primary controller type.
Open a SAT session and enter reset system 4.
After the reboot, the LSP should be registered with the
primary controller and in a few minutes translations
should be synchronized.