Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
MR-J3-_T_
No.
Name and function
PD20
Function selection D-1
Select the stop processing at forward rotation stroke end
(LSN)/reverse rotation stroke end (LSN) OFF and the
base circuit status at reset (RES) ON.
0 _ _ x:
Stopping method used when forward rotation stroke end
(LSP), reverse rotation stroke end (LSN) device or
software limit is valid
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Deceleration to a stop by deceleration time
constant
3: Sudden stop (Stop by remaining move distance clear)
0_ x _:
Selection of base circuit status at reset (RES)ON
0: Base circuit not switched off
1: Base circuit switched off
0 x _ _:
Stopping method used when software limit is valid
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Deceleration to a stop by deceleration time
constant
3: Sudden stop (Stop by remaining move distance clear)
As in the following parameter settings, when the home
position is lost by the forward rotation stroke end, reverse
rotation stroke end, or the software limit detection, the
home position return completion (ZP) turns on by turning
OFF/ON the servo-on (SON). In this case, there is no
need to perform the home position return again.
1. In absolute position detection system
[Pr. PA03]: _ _ _ 1 (Select the absolute position
detection system)
[Pr. PA01]: _ _ _ 0 (Select the absolute value
command system)
2. In incremental system
[Pr. PA03]: _ _ _ 0 (Select the incremental system)
[Pr. PA01]: _ _ _ 0 (Select the absolute value
command system)
[Pr. PA04]: _ _ _ 1 (Follow-up valid)
Initial
No.
value
0010h
PD30
Function selection D-1
_ _ _ x:
Stop method selection for LSP (Forward rotation stroke
end) off or LSN (Reverse rotation stroke end) off
Select a stop method for LSP (Forward rotation stroke
end) off or LSN (Reverse rotation stroke end) off.
0: Quick stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (deceleration to a stop by deceleration time
constant)
3: Quick stop (stop by clearing remaining distance)
_ _ x _:
Base circuit status selection for RES (Reset) on
0: Base circuit shut-off
1: No base circuit shut-off
_ x _ _:
Stop method selection at software limit detection
Select a stop method selection at software limit
detection. (Refer to section 7.6.)
0: Quick stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (deceleration to a stop by deceleration time
constant)
3: Quick stop (stop by clearing remaining distance)
x _ _ _:
Enabled/disabled selection for a thermistor of servo
motor
0: Enabled
1: Disabled
The setting in this digit will be disabled when using a
servo motor without thermistor.
6 - 77
MR-J4-_A_-RJ
Name and function
Initial
value
0h
0h
0h
0h