Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
MR-J3-_T_
No.
Name and function
PA02
Regenerative option
This parameter is made valid when power is switched off,
then on after setting.
Wrong setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the
servo amplifier, [AL. 37 parameter error] occurs.
Set this parameter when using the regenerative option,
brake unit, power regeneration converter, or power
regeneration common converter.
0 0 x x:
Selection of regenerative option
00: Regenerative option is not used
・For the servo amplifiers of 100 W, a regenerative
resistor is not used.
・For servo amplifier of 0.2 kW to 7 kW, built-in
regenerative resistor is used.
・Supplied regenerative resistors or regenerative option
is used with the servo amplifier of 11 kW to 22 kW.
01: FR-BU2-(H)/FR-RC-(H)/FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required)
08: MR-RB31
09: MR-RB51 (Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4 (Cooling fan is required)
82: MR-RB3G-4 (Cooling fan is required)
83: MR-RB5G-4 (Cooling fan is required)
84: MR-RB34-4 (Cooling fan is required)
85: MR-RB54-4 (Cooling fan is required)
FA: When the supplied regenerative resistors or the
regenerative option is cooled by the cooling fan to
increase the ability with the servo amplifier of 11 kW
to 22 kW.
PA03
Absolute position detection system
This parameter is made valid when power is switched off,
then on after setting, or when the controller reset has
been performed.
Set this parameter when using the absolute position
detection system.
0 0 0 x:
Selection of absolute position detection system
0: Used in incremental system
1: Used in absolute position detection system
Initial
No.
value
0000h
PA02
Regenerative option
Select a regenerative option.
Incorrect setting may cause the regenerative option to
burn.
If a selected regenerative option is not for use with the
servo amplifier, [AL. 37 Parameter error] occurs.
00: Regenerative option is not used.
For the servo amplifiers of 100 W, a regenerative
resistor is not used.
For servo amplifier of 0.2 kW to 7 kW, built-in
regenerative resistor is used.
Supplied regenerative resistors or regenerative
option is used with the servo amplifier of 11 kW to
22 kW.
01: FR-RC-(H)/FR-CV-(H)/FR-BU2-(H)
When you use FR-RC-(H) or FR-CV-(H), select
"Mode 2 (_ _ _ 1)" of "Undervoltage alarm detection
mode selection" in [Pr. PC27].
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required.)
08: MR-RB31
09: MR-RB51 (Cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (Cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (Cooling fan is required.)
82: MR-RB3G-4 (Cooling fan is required.)
83: MR-RB5G-4 (Cooling fan is required.)
84: MR-RB34-4 (Cooling fan is required.)
85: MR-RB54-4 (Cooling fan is required.)
91: MR-RB3U-4 (Cooling fan is required.)
92: MR-RB5U-4 (Cooling fan is required.)
FA: When the supplied regenerative resistors or the
regenerative option is cooled by the cooling fan to
increase the ability with the servo amplifier of 11 kW
to 22 kW.
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0000h
PA03
Absolute position detection system
_ _ _ x:
Absolute position detection system selection
Set this digit when using the absolute position detection
system.
0: Disabled (incremental system)
1:Enabled (absolute position detection system)
2: Not used for positioning mode.
Setting a value other than "0" and "1" will trigger [AL. 37
Parameter error].
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
6 - 45
MR-J4-_A_-RJ
Name and function
Initial
value
00h
0h
0h
0h
0h