Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
(4) MR-J4-_A_-RJ
The following illustration is an example of MR-J4-20A-RJ.
R S T
(Note 2)
Power supply
Molded-case
circuit breaker
(MCCB)
(Note 3)
Magnetic
contactor
(MC)
(Note 1)
Line noise filter
(FR-BSF01)
L1
L2
L3
Power factor
improving DC
reactor
(FR-HEL)
P+
Regenerative
option
C
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P3 and P4.
2. A 1-phase 200 V AC to 240 V AC power supply may be used with the servo amplifier of MR-J4-200A-RJ or less. For 1-phase
200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For power supply specifications, refer to
section 1.3 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
3. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
4. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
D (Note 4)
P3
P4
L11
L21
CN5
CN6
CN3
CN8
CN1
U
V
W
CN2
CN2L
CN4
6 - 23
Personal
computer
MR Configurator2
Analog monitor
To RS-422 communication
controller, parameter unit, etc.
To safety relay or
MR-J3-D05 safety
logic unit
Manual pulse generator
Junction terminal block
Servo motor
Battery