Parameter Initial Value Groups - Mitsubishi Electric FR-E800 Series Instruction Manual

Compact, high functionality inverters
Hide thumbs Also See for FR-E800 Series:
Table of Contents

Advertisement

3
Parameters
This chapter explains the function setting for use of this product.
Always read the instructions before use.
The following marks are used to indicate the controls. (Parameters without any mark are valid for all the controls.)
Mark
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
PM
PM
PM
3.1

Parameter initial value groups

• Initial values of parameters of the FR-E800 differ depending on the parameter initial value group. In this Instruction Manual,
Gr.1 indicates the parameter initial value group 1, and Gr.2 indicates the parameter initial value group 2.
• FR-E800 inverters are divided into two groups as shown in the following table.
Parameter initial value groups
Group 1 (Gr.1)
Group 2 (Gr.2)
• The initial values of the following parameters differ depending on the parameter initial value group.
Pr.
3
Base frequency
4
Multi-speed setting (high speed)
19
Base frequency voltage
20
Acceleration/deceleration reference frequency
55
Frequency monitoring reference
66
Stall prevention operation reduction starting frequency
125
Terminal 2 frequency setting gain frequency
126
Terminal 4 frequency setting gain frequency
249
Earth (ground) fault detection at start
301
BCD input gain
303
BIN input gain
505
Speed setting reference
808
Speed limit
1486
Load characteristics maximum frequency
*1
The parameter is available when the plug-in option (FR-A8AX) is installed. For details, refer to the FR-A8AX E kit Instruction Manual.
52
3. Parameters
3.1 Parameter initial value groups
Control method
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control
PM sensorless vector control
Model
FR-E800-1
RS-485 communication, terminal FM
FR-E800-5
RS-485 communication, terminal AM
FR-E800-(SC)EPA
Ethernet communication (Protocol group A)
FR-E800-4
RS-485 communication, terminal AM
FR-E800-(SC)EPB
Ethernet communication (Protocol group B)
Name
Applied motor
Three-phase induction motor
PM motor
Specification
Initial value
Refer to
page
Gr.1
Gr.2
60 Hz
50 Hz
428
60 Hz
50 Hz
234
9999
8888
428
60 Hz
50 Hz
196
60 Hz
50 Hz
270
60 Hz
50 Hz
256
60 Hz
50 Hz
318
60 Hz
50 Hz
318
0
1
246
*1
60 Hz
50 Hz
*1
60 Hz
50 Hz
60 Hz
50 Hz
268
60 Hz
50 Hz
147
60 Hz
50 Hz
261

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents