NOTE
• When torque bias is enabled and Pr.858 = "6", terminal 4 operates as a torque command.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
• When the X13 signal is ON, the torque bias function is disabled.
Parameters referred to
Pr.73 Analog input
selectionpage 310
Pr.178 to Pr.189 (Input terminal function
C38 to C41 (Pr.932, Pr.933) (torque setting voltage (current)
selection)page 328
bias/gain)page 323