Mitsubishi Electric FR-E800 Series Instruction Manual page 274

Compact, high functionality inverters
Hide thumbs Also See for FR-E800 Series:
Table of Contents

Advertisement

Incremen
Monitor item
t and unit
Option input
terminal status 1
(for
*1
communication)
0
Option input
terminal status 2
(for
*1
communication)
0
Option output
terminal status
(for
*1
communication)
0
Motor thermal
0.1%
load factor
Inverter thermal
0.1%
load factor
PID measured
0.1%
value 2
32-bit cumulative
energy (lower 16
1 kWh
bits)
32-bit cumulative
energy (upper 16
1 kWh
bits)
32-bit cumulative
energy (lower 16
0.01 kWh
bits)
32-bit cumulative
energy (upper 16
0.01 kWh
bits)
BACnet valid
APDU counter
1
PID manipulated
0.1%
amount
Dancer main set
*16
0.01 Hz
speed
*1
The monitor code is used for the Mitsubishi inverter protocol, CC-Link, CC-Link IE TSN, and CC-Link IE Field Network Basic.
*2
The monitor code is used for the MODBUS RTU, MODBUS/TCP, and BACnet/IP.
*3
The monitor number is used for the EtherNet/IP and PROFINET.
*4
Indication with a minus sign is not possible via RS-485 communication (Mitsubishi inverter protocol or MODBUS RTU).
*5
To monitor the item on the LCD operation panel (FR-LU08) in the monitor mode, use Pr.774 to Pr.776 or the monitor function of the FR-LU08 for
setting.
*6
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
*7
The actual operation time does not increase if the cumulative running time before power OFF is less than an hour.
*8
Since each readout of the output voltage and output current displayed on the operation panel is a 4-digit number, a value of more than "9999" is
displayed as "----".
*9
The inverter regards the output current which is less than the specified current level (5% of the rated inverter current) as 0 A. Therefore, each
readout of an output current and output power may show "0" if a too small-capacity motor is used as contrasted with the inverter capacity and the
output current falls below the specified value.
*10 Available when the plug-in option is connected.
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
*13
*13
H3A
40258
*14
*14
H3B
40259
*15
*15
H3C
40260
61
H3D
40261
62
H3E
40262
67
H43
40267
H4D
40277
H4E
40278
H4F
40279
H50
40280
83
H53
40283
91
H5B
40291
97
H61
40297
Negative
Monitor
indicatio
number
*4
*2
n (-)
*3
The ON/OFF state of the input terminals X0 to
3A
X15 on the digital input option (FR-A8AX) is
monitored via communication.
The ON/OFF state of the input terminal DY on
3B
the digital input option (FR-A8AX) is monitored
via communication.
The ON/OFF state of the output terminals on the
digital output option (FR-A8AY) or the relay
3C
output option (FR-A8AR) is monitored via
communication.
The accumulated heat value of the motor
thermal O/L relay is displayed.
3D
The Motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter
thermal O/L relay is displayed.
3E
The Inverter overload trip (electronic thermal
relay function) (E.THT) occurs at 100%.
The PID measured value is displayed while the
PID control is enabled (Pr.128 ≠ "0"), even if PID
43
control operating conditions are not satisfied.
(Refer to
4D
4E
The upper or lower 16 bits of the 32-bit
cumulative energy is displayed on each
indication.
Monitoring via communication is available.
4F
50
The count of valid APDU detection is displayed.
53
(Available only for the FR-E800-EPA and FR-
E800-SCEPA.)
The PID control manipulated amount is
5B
displayed. (Refer to
The set speed for main speed during the dancer
61
control operation is displayed.
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
Description
page
389.)
page
389.)
11
12
13
14
15
16
17
18
19
20
273