Pr.
Function
Pr.
group
807
H410
Speed limit selection
808
H411
Speed limit
809
H412
Reverse-side speed limit
Torque limit input method
810
H700
selection
811
D030
Set resolution switchover
Torque limit level
812
H701
(regeneration)
Torque limit level (3rd
813
H702
quadrant)
Torque limit level (4th
814
H703
quadrant)
815
H710
Torque limit level 2
Torque limit level during
816
H720
acceleration
Torque limit level during
817
H721
deceleration
820
G211
Speed control P gain 1
821
G212
Speed control integral time 1 0 to 20 s
822
T003
Speed setting filter 1
*5
G215
Speed detection filter 1
823
Torque control P gain 1
824
G213
(current loop proportional
gain)
Torque control integral time 1
825
G214
(current loop integral time)
826
T004
Torque setting filter 1
828
G224
Model speed control gain
830
G311
Speed control P gain 2
831
G312
Speed control integral time 2 0 to 20 s, 9999
832
T005
Speed setting filter 2
*5
G315
Speed detection filter 2
833
Torque control P gain 2
834
G313
(current loop proportional
gain)
Torque control integral time 2
835
G314
(current loop integral time)
836
T006
Torque setting filter 2
840
G230
Torque bias selection
841
G231
Torque bias 1
842
G232
Torque bias 2
843
G233
Torque bias 3
844
G234
Torque bias filter
845
G235
Torque bias operation time
Torque bias balance
846
G236
compensation
Fall-time torque bias terminal
847
G237
4 bias
Fall-time torque bias terminal
848
G238
4 gain
Name
Setting range
0, 1
0 to 400 Hz
0 to 400 Hz, 9999
0 to 2
0, 10
0% to 400%, 9999
0% to 400%, 9999
0% to 400%, 9999
0% to 400%, 9999
0% to 400%, 9999
0% to 400%, 9999
0% to 1000%
0 to 5 s, 9999
0 to 0.01 s
0% to 500%
0 to 500 ms
0 to 5 s, 9999
0 to 1000 rad/s
0% to 1000%, 9999
0 to 5 s, 9999
0 to 0.01 s, 9999
0% to 500%, 9999
0 to 500 ms, 9999
0 to 5 s, 9999
0 to 3, 9999
600% to 1400%, 9999 1%
600% to 1400%, 9999 1%
600% to 1400%, 9999 1%
0 to 5 s, 9999
0 to 5 s, 9999
0% to 100%, 9999
0% to 400%, 9999
0% to 400%, 9999
Initial
Minimum
Refer
*1
value
setting
to page
increments
Gr.1
Gr.2
1
0
147
0.01 Hz
60 Hz 50 Hz
147
0.01 Hz
9999
147
1
0
114
1
0
114
0.1%
9999
114
0.1%
9999
114
0.1%
9999
114
0.1%
9999
114
0.1%
9999
114
0.1%
9999
114
1%
60%
121
0.001 s
0.333 s
121
0.001 s
9999
316
0.001 s
0.001 s
154
1%
100%
149
0.1 ms
5 ms
149
0.001 s
9999
316
1 rad/s
100 rad/s
124
1%
9999
121
0.001 s
9999
121
0.001 s
9999
316
0.001 s
9999
154
1%
9999
149
0.1 ms
9999
149
0.001 s
9999
316
1
9999
126
9999
126
9999
126
9999
126
0.001 s
9999
126
0.01 s
9999
126
0.1%
9999
126
1%
9999
126
1%
9999
126
3.2 Parameter list (by parameter number)
Customer
1
setting
2
3
4
5
6
7
8
9
10
69
3. Parameters