• The following table shows the command interface for each function in the Network operation mode, determined by the
parameter settings: an external terminal or a communication interface (PU connector, Ethernet connector, or
communication option).
Pr.338 Communication operation command source
Pr.339 Communication speed command source
Frequency setting through communication
Terminal 2
Terminal 4
Low-speed operation command/Remote setting
*1
RL
(setting clear)/Stop-on-contact selection 0
Middle-speed operation command/Remote
*1
RM
setting (deceleration)
High-speed operation command/ Remote setting
*1
RH
(acceleration)
Second function selection/ Stop-on-contact
*1
RT
selection 1
*1
Terminal 4 input selection
AU
*1
Jog operation selection
JOG
*1
External thermal relay input
OH
*1
15-speed selection
REX
*1
Inverter run enable
X10
*1
PU operation external interlock
X12
*1
External DC injection brake operation start
X13
*1
PID control valid
X14
*1
Brake opening completion
BRI
*1
PU/External operation switchover
X16
*1
V/F switchover
X18
*1
Pre-excitation
LX
Output stop
*1
MRS
PU operation interlock
STP
Start self-holding selection
*1
(STOP)
*1
Control mode switchover
MC
*1
Torque limit selection
TL
*1
JOG2
*1
Traverse function selection
X37
*1
Torque bias selection 1
X42
*1
Torque bias selection 2
X43
*1
Trace trigger input
TRG
*1
Trace sampling start/end
TRC
*1
Sequence start
SQ
*1
Fault clear
X51
*1
Forward rotation command
STF
*1
Reverse rotation command
STR
*1
Inverter reset
RES
*1
PU/NET operation switchover
X65
*1
External/NET operation switchover
X66
*1
Command source switchover
X67
*1
PID P control switchover
X72
*1
Magnetic flux decay output shutoff
X74
*1
Emergency stop
X92
0: NET
0:
1:
NET
EXT
NET —
EXT
EXT
NET EXT
NET EXT
NET EXT
NET
Combined
EXT
NET EXT
EXT
EXT
NET
NET EXT
NET
EXT
NET
NET
Combined
EXT
NET
NET
NET
NET
NET
NET
Combined
Combined
EXT or NET
Combined
NET
NET
EXT
EXT
EXT
EXT
NET EXT
NET
Combined
10.3 Start command source and frequency command source during communication operation
1: EXT
2:
0:
1:
2:
EXT
NET
EXT
EXT
NET NET —
NET
EXT
EXT
NET EXT
Pr.59 = "0" (multi-speed), Pr.59
NET EXT
≠ "0" (remote), Pr.270 ="1" (stop-
on-contact)
NET EXT
Pr.270 = "1" (stop-on-contact)
EXT
Combined
EXT
Pr.59 ="0" (multi-speed)
NET EXT
EXT
NET EXT
EXT
EXT
EXT
EXT
Pr.79 ≠ "7"
Pr.79 = "7".
When X12 signal is not assigned.
EXT
EXT
EXT
EXT
EXT
EXT
EXT
EXT
EXT
Pr.414 = "1": Valid when there is
EXT
external or network input.
Pr.414 = "2": External.
EXT
EXT
EXT
NET EXT
EXT
EXT
10. (D) Operation Command and Frequency Command
1
2
Remarks
3
4
5
6
7
8
9
10
229