INVERTER
FR-E800(-E)
INSTRUCTION MANUAL
(FUNCTIONAL SAFETY)
CONTENTS
1. GENERAL DESCRIPTION ............................................ 3
2. INSTALLATION AND WIRING...................................... 4
4. TEST AND CHECKING FAILURE ............................... 11

Advertisement

loading

Summary of Contents for Mitsubishi Electric 800 Series

  • Page 1: Table Of Contents

    INVERTER FR-E800(-E) INSTRUCTION MANUAL (FUNCTIONAL SAFETY) CONTENTS 1. GENERAL DESCRIPTION ..........3 2. INSTALLATION AND WIRING........4 3. EXAMPLE OF SAFETY SYSTEM CONFIGURATION ..8 4. TEST AND CHECKING FAILURE ....... 11 5. SAFETY PARAMETERS OF FR-E800(-E)....12...
  • Page 2 CAUTION  The information of this manual is merely a guide for proper installation.  Mitsubishi Electric cannot assume responsibility for the compliance or the noncompliance to any code, national, local, or otherwise for the proper installation of this equipment.
  • Page 3: General Description

    Features The safety stop function of the Mitsubishi Electric FR-E800(-E) inverter can be used to prevent the inverter from supplying rotational energy to motors. Dual input terminals S1 and S2 can be used to cut off the gate-drive power to the IGBT.
  • Page 4: Installation And Wiring

    IP54 and all interconnection wiring is short and protected against open and short circuit faults. Refer ISO/IEC 13849-2. Installation The safety stop function of the Mitsubishi Electric FR-E800(-E) inverter should be used under the following conditions and environment. Table 2 Conditions and environment for using the safety stop function...
  • Page 5 Wiring The safety related terminals are described in Table 3 and Table 4. Table 3 Safety related terminals Terminal Terminal name Terminal function description Rating   symbol For input of safety stop channel 1 Safety stop input Between S1 and PC (Channel 1) OFF: In safety stop mode Input resistance: 4.7 kΩ...
  • Page 6 Table 4 Truth table of safety related signals Internal Input terminal Output Output signal Inverter Operation panel indication Input safety terminal      running power circuit status SAFE SAFE2 E.SAF   status Output shutoff   ...
  • Page 7 Wiring and ferrule terminal specifications Table 5 Wiring and Ferrule terminal specifications Ferrule terminal model Crimping tool name   Cable gauge (mm AI 0,34-10TQ AI 0,5-10WH 0.75 AI 0,75-10GY CRIMPFOX 6 AI 1-10RD 1.25 / 1.5 AI1,5-10BK 0.75 (for two wires) AI TWIN 2 X 0,75-10GY ...
  • Page 8: Example Of Safety System Configuration

    EXAMPLE OF SAFETY SYSTEM CONFIGURATION FR-E800(-E) configuration example FR-E800(-E) R/L1 S/L2 T/L3 Logic START STOP RESET STOP Gate Emergency Driver IGBTs stop button Gate T1 X1 T0 X0 X3 COM+ COM+ Y1 Y0 COM- Driver NZ2GFSS2-32D NZ2EXSS2-8TE IO24V IO24G IO24V IO24G +24V Fuse...
  • Page 9 Multiple inverter configuration example FR-E800(-E) R/L1 S/L2 T/L3 Logic RESET Gate Emergency Driver IGBTs stop button Gate T1 X1 T0 X0 X3 COM+ COM+ Y1 Y0 COM- Driver NZ2GFSS2-32D NZ2EXSS2-8TE IO24V IO24G IO24V IO24G +24V Fuse Programmable controller CC-Link IE Field Network remote I/O module (with safety functions) NZ2GFSS2 - 32D/NZ2EXSS2 - 8TE FR-E800(-E)
  • Page 10 IGBTs Gate Driver A2(0V) A2(0V) +24V Fuse Mitsubishi Electric safety controller MELSEC-WS series CPU module WS0-CPU0 Safety I/O combined module WS0-XTIO Figure 5 Safety system example of the FR-E800(-E) inverter NOTE • When starting up the system operation, press the RESET switch to reset the safety stop function first.
  • Page 11: Test And Checking Failure

    TEST AND CHECKING FAILURE CAUTION  To avoid system faults, check the safety stop function at least once per year. Also, check the safety stop function at system installation, any software changes, and parameter setting changes. I/O status and inverter operation The FR-A800/F800 inverter’s safety related I/O status obeys the following truth table.
  • Page 12: Safety Parameters Of Fr-E800(-E)

    NOTE • The response time from safety stop signal input to drive shutoff (safe state) is faster than 4 ms. • Hold the ON or OFF status for 2 ms or longer to input signal to terminal S1 or S2. Signal input shorter than 2 ms is not recognized.
  • Page 13 MEMO...
  • Page 14 REVISIONS Revision date Manual number Revision Dec. 2019 BCN-A23488-000-A(E) First edition BCN-A23488-000-A(E)