Mitsubishi Electric FR-E800 Series Instruction Manual page 273

Compact, high functionality inverters
Hide thumbs Also See for FR-E800 Series:
Table of Contents

Advertisement

Incremen
Monitor item
t and unit
Motor load factor
0.1%
Cumulative
0.01 kWh
*8
energy
Torque command 0.1%
Torque current
0.1%
command
Feedback
*10
pulse
Trace status
1
PLC function user
monitor 1
PLC function user
Increment
monitor 2
set in the
register
SD1215
PLC function user
monitor 3
Station number
1
(PU)
Station number
1
(CC-Link)
Power saving
Increment
effect
and unit
vary
depending
Cumulative
on the
energy saving
parameter
settings.
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
*10
terminal status
Option output
*10
terminal status
272
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
24
H18
40224
25
H19
40225
32
H20
40232
33
H21
40233
35
H23
40235
38
H26
40238
40
H28
40240
41
H29
40241
42
H2A
40242
44
H2C
40244
45
H2D
40245
50
H32
40250
51
H33
40251
52
H34
40252
53
H35
40253
54
H36
40254
*11
*11
H0F
40215
*18
55
*12
*12
H10
40216
56
57
Negative
Monitor
indicatio
number
*4
*2
n (-)
*3
The output current value is displayed as a
percentage, considering the inverter rated
18
current value as 100%.
Readout (%) = present output current value /
inverter rated current value × 100
The cumulative energy based on the monitored
19
output power is displayed. Use Pr.170 to reset it.
(Refer to
The torque command value adjusted with Vector
20
control is displayed.
The command value of the current for torque is
21
displayed.
The number of pulses fed back from the encoder
in one cycle of the sampling is displayed (kept
displayed during a stop). (The output voltage is
displayed when a vector control option is not
installed.)
23
The sampling time period varies depending on
the Pr.369 Number of encoder pulses setting.
1050 or less: 1 s,
1051 to 2100: 0.5 s,
2101 to 4096: 0.25 s
The trace status is displayed. (Refer to
26
418.)
The user-designated monitor item is displayed
28
using the PLC function.
Each value of the following special registers is
29
displayed.
SD1216: displayed with the setting value "40",
SD1217: displayed with the setting value "41",
SD1218: displayed with the setting value "42"
2A
(Refer to the PLC Function Programming
Manual.)
The station number of the inverter enabling
communication via the PU connector is
2C
displayed. (Available only for the standard
model.)
The station number of the inverter enabling CC-
2D
Link communication is displayed. ("0" is
displayed when the FR-A8NC is not installed.)
32
The energy saving effect monitoring is enabled.
The item to monitor is selectable from among
the saved power, the average energy saving,
and the energy cost savings. Some of them can
33
be displayed as a percentage according to the
parameter settings. (Refer to
34
The set point, measured value, and deviation
35
during PID control operation is displayed. (Refer
to
page
36
The ON/OFF state of the input terminals on the
F
inverter is displayed. (Refer to
details of indication on the operation panel.)
The ON/OFF state of the output terminals on the
10
inverter is displayed. (Refer to
details of indication on the operation panel.)
The ON/OFF state of the input terminals on the
digital input option (FR-A8AX) is displayed on
the operation panel. (Refer to
details.)
The ON/OFF state of the output terminals on the
digital output option (FR-A8AY) or the relay
output option (FR-A8AR) is displayed on the
operation panel. (Refer to
Description
page
276.)
page
286.)
389.)
page 275
page 275
page 275
page 275
for details.)
page
for
for
for