Setting
Signal
value
name
Pr.178
74
X74
○
92
X92
○
9999
No function
○
○: Assignment available, ─: Assignment unavailable (no function)
Adjusting the response of input terminals (Pr.699)
• Response of the input terminals (physical terminals) can be delayed in a range between 5 to 50 ms. (The following is the
operation example of the STF signal.)
ON
STF
Pr.699
9999
Pr.699
NOTE
• The Pr.699 setting is invalid (no filter) for the following signals.
— Input signals which are already in the ON state when the power is turned ON
— Input signals used for the PLC function
— Output stop (MRS) signal
FR-E800
Pr.180 to
Pr.185 to
Pr.179
Pr.184
○
○
○
○
○
○
○
○
○
Time
OFF
Pr.699
FR-E800-E
Pr.178
Pr.179
Pr.189
○
○
○
○
○
○
13. (T) Multi-Function Input Terminal Parameters
13.6 Input terminal function selection
FR-E800-
SCE
Pr.180 to
Pr.180 to
Pr.189
Pr.189
○
○
○
○
○
○
331
11
12
13
14
15
16
17
18
19
20