3.4
Parameter list (by function group number)
 E: Environment setting
parameters
Parameters for the inverter operating environment.
Pr. group
Pr.
E000
168
E001
169
E020
1006
E021
1007
E022
1008
E023
269
E080
168
E081
169
E100
E101
75
E102
E103
145
E104
990
E105
991
E107
75
E200
161
E201
295
E202
40
E300
30
E301
570
E400
77
E410
296
E411
297
E415
1499
E420
888
E421
889
E430
998
E431
999
E440
160
E441
172
E442
173
E443
174
E600
72
E601
240
E602
260
E700
255
80
3. Parameters
3.4 Parameter list (by function group number)
Name
Parameter for manufacturer setting. Do not
set.
Parameter for manufacturer setting. Do not
set.
Clock (year)
Clock (month, day)
Clock (hour, minute)
Parameter for manufacturer setting. Do not
set.
Parameter for manufacturer setting. Do not
set.
Parameter for manufacturer setting. Do not
set.
Reset selection
Disconnected PU detection
PU stop selection
PU display language selection
PU buzzer control
PU contrast adjustment
Reset limit
Frequency setting/key lock
operation selection
Frequency change increment
amount setting
RUN key rotation direction
selection
Regenerative function
selection
Multiple rating setting
Parameter write selection
Password lock level
Password lock/unlock
Parameter for manufacturer setting. Do not
set.
Free parameter 1
Free parameter 2
PM parameter
initialization
Simple
Simple
Simple
Automatic parameter
setting
Simple
Simple
Simple
User group read
selection
Simple
Simple
Simple
User group registered display/
batch clear
User group registration
User group clear
PWM frequency selection
Soft-PWM operation selection
PWM frequency automatic
switchover
Life alarm status display
Pr. group
Pr.
E701
256
E702
257
Refer
to page
E703
258
E704
259
E705
506
158
158
E706
507
158
E708
509
E709
198
E710
503
E711
504
E720
555
E721
556
161
E722
557
164
 F: Settings for acceleration/
165
deceleration
166
161
Parameters
167
characteristics.
169
Pr. group
Pr.
170
F000
20
442
F001
21
171
F002
16
173
175
F003
611
175
F010
7
F011
8
178
178
F020
44
104
F021
45
179
F022
147
F040
1103
181
F070
791
181
181
F071
792
181
F100
29
184
184
F101
59
184
F102
13
186
F103
571
Name
Inrush current limit circuit life
display
Control circuit capacitor life
display
Main circuit capacitor life
display
Main circuit capacitor life
measuring
Display estimated main circuit
capacitor residual life
Display ABC relay contact life
Display power cycle life
Display corrosion level
Maintenance timer
Maintenance timer warning
output set time
Current average time
Data output mask time
Current average value monitor
signal output reference current
for
the
motor
acceleration/deceleration
Name
Acceleration/deceleration
reference frequency
Acceleration/deceleration time
increments
Jog acceleration/deceleration
time
Acceleration time at a restart
Acceleration time
Simple
Simple
Simple
Deceleration time
Simple
Simple
Simple
Second acceleration/
deceleration time
Second deceleration time
Acceleration/deceleration time
switching frequency
Deceleration time at
emergency stop
Acceleration time in low-speed
range
Deceleration time in low-speed
range
Acceleration/deceleration
pattern selection
Remote function selection
Starting frequency
Holding time at a start
Refer
to page
186
186
186
186
186
186
186
186
190
190
191
191
191
Refer
to page
196
196
232
403,
408
196
196
196,
396
196,
396
196
196
196
196
201
203
207,
208
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents