Mitsubishi Electric FR-E800 Series Instruction Manual page 275

Compact, high functionality inverters
Hide thumbs Also See for FR-E800 Series:
Table of Contents

Advertisement

*11 The details of bits for the input terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
b15
Ethernet model
-
-
b15
Safety communication model
-
-
*12 The details of bits for the output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
b15
Ethernet model
-
-
b15 Safety communication model
-
-
*13 The details of bits for the option input terminal status 1 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX.) Every bit is 0
(OFF) when the option is not installed.
b15
X15
X14
*14 The details of bits for the option input terminal status 2 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX. "—" denotes an
indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
*15 The details of bits for the option output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AY/A8AR. "—" denotes
an indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
*16 The increment varies depending on the Pr.53 setting. (Refer to
*17 The monitored values are retained even if an inverter fault occurs. Resetting clears the retained values.
*18 Parameter setting is not valid to set the item as the main monitor item on the LCD operation panel (FR-LU08). Use the monitor function of the
FR-LU08 for the setting.
 Monitor display for operation panel (Pr.52, Pr.774 to Pr.776)
• When Pr.52 = "0" (initial value), the monitoring of output frequency, output current, output voltage and fault display can be
selected in sequence by pressing the SET key.
• The Load meter, motor excitation current and motor load factor are displayed on the second monitor (output current)
position, among the monitors set in Pr.52. Other monitors are displayed in the third monitor (output voltage) position.
• The monitor displayed at power ON is the first monitor (the output frequency monitor, according to the initial value). Display
the monitor you want to display on the first monitor and hold down the SET key for 1 second. To return to the output
frequency monitor, display the output frequency monitor and hold down the SET key for 1 second.
Power-on monitor (first monitor)
Output frequency monitor
For example, when Pr.52 = "20" (cumulative energization time), the monitor is displayed on the operation panel as shown
below.
• Power-on monitor (first monitor)
Output frequency monitor
274
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
-
-
-
RES
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X13
X12
X11
X10
-
-
-
-
-
-
-
-
Second monitor
Output current monitor
• Second monitor
Output current monitor
-
-
MRS
RH
-
-
-
-
-
-
-
-
-
-
-
SO
-
-
SO
-
-
-
-
-
X9
X8
X7
X6
-
-
-
-
RA3
RA2
RA1
Y6
page
268).
Third monitor
Output voltage monitor
• Third monitor
Cumulative energization time monitor
-
-
RM
RL
-
-
-
-
-
-
-
-
-
-
ABC
FU
ABC
-
-
-
ABC
-
-
-
X5
X4
X3
X2
-
-
-
-
Y5
Y4
Y3
Y2
Fault monitor
With fault
• Fault monitor
With fault
b0
STR
STF
b0
DI1
DI0
b0
-
-
b0
-
RUN
b0
-
-
b0
-
-
b0
X1
X0
b0
-
DY
b0
Y1
Y0