(C) Motor Constant Parameters
Purpose
To select the motor to be used
To maximize the performance of the
induction motor
To maximize the performance of the
PM motor
To perform high accuracy operation
without being affected by temperature
and high-torque/ultra-low speed
To use the motor with encoder
To detect loss of encoder signals
14.1

Applied motor

By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay function is set according to the motor.
When the Advanced magnetic flux vector control, Real sensorless vector control, Vector control, or PM sensorless vector
control is selected, the motor constant necessary for control (for SF-PR, SF-PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-
V5RU (1500 r/min series), GM-[], GM-DZ, or GM-DP) is also selected at the same time.
Pr.
71
Applied motor
C100
450
Second applied motor
C200
*1
The setting range for the 575 V class is "0, 3, 5, 6, 10, 13, 15, 16, 30, 33, 8090, 8093, 9090, and 9093".
340
14. (C) Motor Constant Parameters
14.1 Applied motor
Applied motor
Offline auto tuning
PM motor offline auto
tuning
Online auto tuning
Encoder
specifications
Signal loss detection
Name
Initial value
0
9999
Parameter to set
P.C100, P.C200
P.C100 to P.C105,
P.C107, P.C108,
P.C110, P.C120 to
P.C126, P.C182,
PC188, P.C200 to
P.C205, P.C207,
P.C208, P.C210,
P.C220 to P.C226,
P.C282, P.C288
P.C100 to P.C108,
P.C110, P.C120,
P.C122, P.C123,
P.C126, P.C130 to
P.C133, P.C135,
P.C150, P.C182,
P.C185, P.C200 to
P.C208, P.C210,
P.C220, P.C222,
P.C223, P.C226,
P.C230 to P.C233,
P.C235, P.C282,
P.C285
P.C111, P.C211
P.C140, P.C141
P.C148
Setting range
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
30, 33, 40, 43, 50, 53, 70, 73,
1800, 1803, 8090, 8093, 9090,
*1
9093
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
30, 33, 40, 43, 50, 53, 70, 73,
1800, 1803, 8090, 8093, 9090,
*1
9093
9999
Pr.71, Pr.450
340
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84, Pr.90 to
Pr.94, Pr.96, Pr.450,
Pr.453 to Pr.463,
345
Pr.707, Pr.717, Pr.720,
Pr.724, Pr.737, Pr.741,
Pr.744, Pr.745, Pr.859,
Pr.860
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463, Pr.702,
355
Pr.706, Pr.707, Pr.711,
Pr.712, Pr.717, Pr.721,
Pr.724, Pr.725, Pr.738
to Pr.746, Pr.859,
Pr.860, Pr.1002,
Pr.1412, Pr.1413
Pr.95, Pr.574
362
Pr.359, Pr.369
365
Pr.376
368
Description
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
Refer to page