Monitor value
*1
0 or no display
1
2
*1
The value(s) "0" to the left of the leftmost non-zero value is(are) not shown in the monitor display. For example, if no trace data is in internal RAM,
sampling retry is not performed, no trigger is detected, and trace operation is performed, "1" appears. (not "0001")
• During trace operation, the Trace status (Y40) signal can be output.
To use the Y40 signal, set "40" (positive logic) or "140" (negative logic) in one of Pr.190 to Pr.196 (Output terminal
function selection) to assign function to an output terminal.
NOTE
• Changing the terminal assignment using Pr.190 to Pr.196 (Output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.52 Operation panel main monitor
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
424
15. (A) Application Parameters
15.12 Trace function
Fourth digit
No trace data in internal RAM
Trace data in internal RAM
selectionpage 270
selection)page 310
selection)page 292
Trace status
Third digit
Sampling retry not
Trigger not detected
performed
Sampling retry performed
Trigger detected
Sampling retry count excess —
Second digit
First digit
Tracing stopped
Trace operation