 Alphabet (calibration parameters, etc.)
Function
Pr.
group
C0
M310
*6
(900)
C1
M320
*6
(901)
C2
T200
*6
(902)
C3
T201
*6
(902)
125
T202
*6
(903)
C4
T203
*6
(903)
C5
T400
*6
(904)
C6
T401
*6
(904)
126
T402
*6
(905)
C7
T403
*6
(905)
C38
T410
*6
(932)
C39
T411
*6
(932)
C40
T412
*6
(933)
C41
T413
*6
(933)
C42
A630
*6
(934)
C43
A631
*6
(934)
C44
A632
*6
(935)
C45
A633
*6
(935)
PR.CL
ALLC
ER.CL
PR.CH
PM
AUTO
PR.MD
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
*2
Differs depending on the capacity.
6%: FR-E820-0050(0.75K) or lower, FR-E840-0026(0.75K) or lower, and FR-E820S-0050(0.75K) or lower
5%: FR-E860-0017(0.75K)
4%: FR-E820-0080(1.5K) to FR-E820-0175(3.7K), FR-E840-0040(1.5K) to FR-E840-0095(3.7K), and FR-E820S-0080(1.5K) or higher
3%: FR-E820-0240(5.5K) or higher, FR-E840-0120(5.5K) or higher, FR-E860-0027(1.5K), and FR-E860-0040(2.2K)
2%: FR-E860-0061(3.7K) or higher
*3
Differs depending on the capacity.
5 s: FR-E820-0175(3.7K) or lower, FR-E840-0095(3.7K) or lower, FR-E860-0061(3.7K) or lower, and FR-E820S-0110(2.2K) or lower
10 s: FR-E820-0240(5.5K) or higher, FR-E840-0120(5.5K) or higher, and FR-E860-0090(5.5K) or higher
76
3. Parameters
3.2 Parameter list (by parameter number)
Pr.
Name
FM terminal calibration
[E800-1]
AM terminal calibration
[E800-4][E800-5]
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting
bias
Terminal 2 frequency setting
gain frequency
Terminal 2 frequency setting
gain
Terminal 4 frequency setting
bias frequency
Terminal 4 frequency setting
bias
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting
gain
Terminal 4 bias command
(torque/magnetic flux)
Terminal 4 bias (torque/
magnetic flux)
Terminal 4 gain command
(torque/magnetic flux)
Terminal 4 gain (torque/
magnetic flux)
PID display bias coefficient
PID display bias analog value 0% to 300%
PID display gain coefficient
PID display gain analog value 0% to 300%
Parameter clear
All parameter clear
Fault history clear
Initial value change list
PM initialization
Automatic parameter setting
Group parameter setting
Minimum
Setting range
setting
increments
0 to 590 Hz
0.01 Hz
0% to 300%
0.1%
0 to 590 Hz
0.01 Hz
0% to 300%
0.1%
0 to 590 Hz
0.01 Hz
0% to 300%
0.1%
0 to 590 Hz
0.01 Hz
0% to 300%
0.1%
0% to 400%
0.1%
0% to 300%
0.1%
0% to 400%
0.1%
0% to 300%
0.1%
0 to 500, 9999
0.01
0.1%
0 to 500, 9999
0.01
0.1%
(0), 1
1
(0), 1
1
(0), 1
1
1
0
1
(0), 1, 2
1
page
52).
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
283
283
0 Hz
318
0%
318
60 Hz 50 Hz
318
100%
318
0 Hz
318
20%
318
60 Hz 50 Hz
318
100%
318
0%
318
0%
318
150%
318
100%
323
9999
393
20%
393
9999
393
100%
393
0
456
0
456
0
458
0
52
0
104
179
0
78