Operation
9.3 Controlling via the AOP30 operator panel
9.3.3

Parameterization menu

You can adjust the unit settings in the Parameterization menu.
Two display types can be selected in the AOP:
1. All parameters
All the parameters present in the unit are listed with this option. The DO to which the
parameter currently selected belongs (inverted) is displayed in curly brackets in the top
left of the screen. With this display type, the response time for turning a page is
dependent on the number of DOs and is generally longer than with parameter lists that
only display one DO.
2. DO selection
With this display type, you can pre-select a DO so that only the parameters for this DO
are listed. (The expert list in STARTER is only displayed in this DO view.)
In both cases, the set access level governs which parameters are displayed. You can set the
access level in the menu for safety inhibits, which can be called up using the key button.
The parameters for access levels 1 and 2 are sufficient for simple applications.
At access level 3 ("Expert"), you can change the structure of the function by interconnecting
BICO parameters.
The Parameterization menu offers four options:
● Individual DO
Shows the parameters of a DO to be selected in advance
● All DOs
Shows the parameters of all DOs in list format (as described previously)
● Data set selection
Figure 9-19
In the "AOP" column of the "Data set selection" screen, you can choose which of the data
sets selected is currently displayed on the operator panel. The data set numbers that are
set in the drive (i.e. are currently active) are displayed in the "Drive" column. The "Max"
column shows the maximum data set number to be entered for the AOP30 display.
In parameter lists, data set parameters are indicated by the letter c, d, or e between the
parameter number and parameter designator. The number at the right of the first row
from the top shows which data set a highlighted parameter comes from.
384
Data set selection
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A