6.9.3

Electronics power supply

Table 6- 28
Terminal type, electronic power supply
Type
Connection capacity
Stripped length
Tightening torque
Table 6- 29
Assignment of terminals for the electronic power supply
Terminal
Connection
XP1
5U1
5W1
5N1
or
5U1
5W1
5N1
"Power interface with AC electronic power supply" module
Note
In the case of line supply voltages that fall outside the tolerance range (see Chapter
"Technical data (Page 39)"), the electronics supply voltage, field circuit line supply
connection, and the unit fan connection must be adapted to the permissible value using
transformers. It is absolutely essential that you use an isolation transformer for rated line
voltages above 480 V for safe electrical isolation.
The rated value of the supply voltage for the armature circuit (index 0) and for the field circuit
(index 1) must be set at p50078.
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
MSTB 2.5/CIF plug-in terminal
Rigid/flexible/conductor sizes (mm
Flexible with ferrule with/without plastic sleeve: 0.25 - 2.5 / 0.25 - 2.5 mm
Multi-conductor connection (two conductors of the same type and with same cross-section):
Rigid/flexible: 0.2 - 1 / 0.2 - 1.5 mm
Flexible with ferrule with/without plastic sleeve: 0.25 - 1 / 0.5 - 1.5 mm
7 mm
0.5 - 0.6 Nm
Function
400 V infeed
230 V infeed
6.9 Assignment of terminals and connectors
/mm
/AWG): 0.2 - 2.5 / 0.2 - 2.5 / 24 - 12
2
2
2
Technical specifications
2 AC 380 V (-25%) to 480 V (+10%); In = 1 A
(-35% for 1 min)
Internal protection with F200, F201 on the "Power interface
with AC electronic power supply" module
External protection max. 6 A, characteristic C recommended
1 AC 190 V (-25%) to 240 V (+10%); In = 2 A
(-35% for 1 min)
Internal protection with F200, F201 on the "Power interface
with AC electronic power supply" module
External protection max. 6 A, characteristic C recommended