7.3 Sensor Module Cabinet-Mounted SMC30
NOTICE
Damage when connecting an impermissible number of encoder systems
Damage results when more than the maximum permissible number of encoder systems are
connected to a Sensor Module.
• Only connect one encoder system to a Sensor Module.
Note
Reduced interference immunity through equalization currents via the electronic ground
Make sure there is no electrical connection between the encoder system housing and the
signal lines and the sensor system electronics.
If this is not carefully observed, under certain circumstances the system will not be able to
reach the required interference immunity level (there is then a danger of equalization
currents flowing through the electronics ground).
NOTICE
Damage through the use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
• Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
Note
Malfunctions due to polluted DRIVE-CLiQ interfaces
Malfunctions can occur in the system through the use of polluted DRIVE-CLiQ interfaces.
• Cover unused DRIVE-CLiQ interfaces with the supplied blanking covers.
Note
The safety instructions on the Sensor Module must be observed.
After the product has reached the end of its service life, the individual parts should be
disposed of in compliance with local regulations.
208
respective application.
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A