⇒ Select the PROFIdrive telegram type.
● 1: Standard telegram 1, PZD-2/2
● 3: Standard telegram 3, PZD-5/9
● 4: Standard telegram 4, PZD-6/14
● 20: SIEMENS telegram 20, PZD-2/6
● 220: SIEMENS telegram 220, PZD-10/10
● 352: SIEMENS telegram 352, PZD-6/6
● 999: Free telegram configuration with BICO (default setting)
Note
If a standard telegram is selected, BICO interconnections are triggered which cannot be re-
parameterized. If, e.g. p0840 is to be changed again, a switchover to free telegram
configuration has to be made first.
⇒ Click Next >