en | Networking via Ethernet
6

Networking via Ethernet

6.1

IP settings

To modify values for Ethernet settings or to configure these for the first time, select in the
start menu:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Notice!
Changes to Ethernet settings take effect after restarting the panel.
6.2

Diagnostics

Diagnostics information and help materials for pinpointing problems in a network can be
found under menu item Diagnostics - Network services. Information is provided on the
following topics:
2020-07 | 3.0 | F.01U.378.877
Configuration
Network services
Ethernet. The Configure Ethernet screen is displayed.
Activate the checkbox Use Ethernet settings.
Select IP settings. The values for IP address, network screen, default gateway, multicast
address and port number are indicated. When you commission the panel controller for
the first time, all values are set to "0".
Select Default settings to overwrite these values with the default settings saved in the
panel controller (recommended!). The IP address in this case corresponds to the stored
default IP address, the last number of which matches the physical node address (PNA/
RSN) that was set during installation at the panel controller.
If the planned configuration requires a change to the default values:
Touch the field containing the value to be changed. Use the arrow keys on the operating
panel to select the desired numbers and modify the values using the number keys on the
alphanumeric keypad.
Or:
Touch the Change field. Touch the field containing the number block to be changed. Use
the arrow keys on the operating panel to select the desired numbers and modify the
values using the number keys on the alphanumeric keypad.
Touch OK to apply the changes or Cancel to discard the changes. You are returned to the
initial Configuration IP screen.
Select OK to apply the changes to the IP settings or Cancel to discard the changes. You
are returned to the Configure Ethernet screen.
Select OK to confirm application of the Ethernet settings (Use Ethernet settings) or
Cancel to exit the screen without activating the Ethernet settings.
Routing table
Information concerning the accessibility of all nodes within the system network via the
respective interface.
Ethernet ports
Information concerning different parameters and the status of the two Ethernet
interfaces available at the panel controller.
Send ping command
Sending of a ping command to a specific IP address to check the availability of other
nodes in the network.
Consistency check